Application

Medical Waste

Cabinet-type and industrial shredders — 50 kg/hr to 10 t/hr — plus a two-stage 2–3 t/hr recycling line.

Medical Waste
Medical Waste — detail 1
Medical Waste — detail 2
Medical Waste — detail 3
Medical Waste — detail 4

TIMO offers a full range of medical-waste equipment. Slow-speed, high-torque shredders reduce fabrics, glass, plastics and stainless-steel instruments. After shredding, material is ready for thermal destruction, or it can be sterilized and disposed of with regular waste.

Two-stage recycling line (about 2–3 t/hr): autoclave sterilizer → 660L bin-lifter → primary shredder (60–200 mm) → conveyor → vertical two-stage two-shaft shredder (10–30 mm) → discharge auger to truck. The worker pulls the 660L bin from the autoclave, rolls it into the lifter, and the line runs from there.

Cabinet-type units take 0.6–0.7 m³ and roll on casters for pharmacies and clinics (pill bottles, syringes, blister packs). Industrial models from 200 kg/hr to 10 t/hr accept bag or autoclave-cart batch loading and render waste unrecognizable — volume down as much as 70% before landfill.

Process flow

  1. 1Waste is sterilized in the autoclave chamber
  2. 2660L bin is drawn out and rolled into the bin-lifter
  3. 3Primary shredder reduces material to 60–200 mm
  4. 4Conveyor feeds the vertical two-stage shredder (final 10–30 mm)
  5. 5Discharge auger loads a truck for landfill or further recycling

Line equipment

Autoclave sterilizer
Autoclave sterilizer
Two-stage shredder line
Two-stage shredder line
Normal medical waste
Normal medical waste
Pharmacy pill bottles